Phase- Controlled Thyristor Converters
iPES-Home
| |
Commutation / Converter Equivalent Circuit
(1)
Drag with the mouse the tip of the red arrow in the time-behavior applet to change the firing angle
of the converter.
(2)
Drag with the mouse the red part of the inductor-symbol in the power circuit applet to
change the value of the stray-inductor proportional to its length.
(3)
Drag with the mouse the operating point (red dot) in the diagram (top, right-hand applet) to change
the constant load current defined by the ideal current source.
(4)
Drag the time-marker (vertical red line) in the top time-behavior applet to define a certain time
where the current flow is animated in the power circuit applet.
|